Our goal is to provide readers with pump application and performance insights that will assist in improving operations and saving money. If you have a comment please share it with us. If you like our newsletter, please share it with a friend!

What happens when two pumps independently feed a common system (parallel operation)? Is the flow twice that of a single pump system? Do the pumps share the load equally? In this month’s issue we discuss the facts about parallel pump operation.

  Dale B. Andrews - Editor

Get Acrobat Reader

Printable Version

Single vs. Parallel Operation
Parallel operation may be required to meet variable demands, such as flood control, or to satisfy a temporary condition that occurs such as when changing over pumps in an uninterruptible process.
Image of a large Parallel pump installation
Image of a perfromance curve for a single pump vs two pumps overlayed with a system curve that intersects both. Figure 2 illustrates the characteristic of single vs. parallel operation. Two identical pumps operating in parallel are capable of producing twice the flow of a single pump at any given TDH. However, the actual flow rate realized in the system is dictated by the intersection of the system curve with the pump curve. Unless the system curve is variable, the flow increase may not be that significant.
For example, assume that there is a set of fixed spray nozzles, where the system resistance is purely frictional, and varies only as a result of flow change. When a second pump is introduced, resistance in the system increases as the flow increases. The flow will increase only to where the system curve intersects the two-pump curve, as shown in figure 3. The amount of flow increase is dictated not only by the system curve, but also by the steepness of the pump curves. Pumps with flat curves will have less TDH separation than pumps with steep curves and therefore will have less of a flow rate change. Illustration of curves for pumps parrallel showing how curve slope will affect the amount of additional flow for two pumps instead of one with a fixed system curve
Curves showing how additional flow through parallel pump operation works well when there is a variable system curve such as found with fire pumps or control valves A fire pump installation would be an example of a system that has a variable system curve. Figure 4 illustrates this. Each time an additional fire nozzle is activated, the system resistance is decreased. This causes the system curve to move to a higher flow on the pump curve, increasing the kW load on the pump and decreasing the amount of TDH available. Eventually, another fire pump may need to be activated to maintain the system pressure as more nozzles come on line.
Continuously Rising TDH Curves
Pump specifications often dictate that pumps have a continuously rising head curve to shut-off. It is a characteristic of certain pumps to have a head curve that droops as the flow approaches shut-off. This characteristic is quite prevalent in pumps with specific speeds under 30 (Ns~1550 US units). Curves with a drooping shut-off characteristic may experience load sharing problems when operating in parallel with other pumps.

Illustration of a non continuously rising centrifugal pump head curve showing how a second pump can stall at a low flow when trying to start in parallel with another pump.In figure 5, the system and TDH curves intersect at a TDH that is greater than the shut-off TDH value and at a lower TDH than the max TDH of the curve. When the second pump starts, the flowrate will increase only to the first point where the TDH matches the pressure in the system. Because the first pump’s operating TDH point is mirrored by another at a lower flow, the second pump’s flowrate will not increase beyond the low flow point. At best, the pumps will share the load unevenly, with the second pump operating at a lower efficiency. Worse, the 2nd pump might operate at less than its minimum allowable design flow, resulting in damage to the equipment and possible injury to personnel.

Illustration of the effect of pump wear on parallel pump operation. A similar condition may exist when one pump is worn. As a pump wears, the amount of TDH produced at any given flow rate diminishes. If the new pump’s intersection with the system curve is above the shut-off TDH of the worn pump, it will force the worn pump into a shut-off condition.
Load sharing problems, between pumps operating in parallel, may increase wear, reduce seal and bearing life, lower operating efficiencies and limit process operations. In the absence of any flow measurement capability, an uneven performance distribution, between pumps operating in parallel, is easier to avoid than to detect. Proper pump selection for parallel operation and pump performance monitoring are the best tools in avoiding load sharing problems and maintaining a well operating parallel pump installation.